OI 0505931
Electronics International Inc.
63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • www.Buy-EI.com
5/5/93
Rev. H: 2/17/05
Operating Instructions
(FP-5 and FP-5L)
Fuel Flow / Pressure
You must read this manual before installing or operating the instrument. This
manual contains warranty and other information that may affect your decision
to install this product and/or the safety of your aircraft.
®
Zobrazit stránku 0
1 2 3 4 5 6 ... 26 27

Shrnutí obsahu

Strany 1 - Fuel Flow / Pressure

OI 0505931Electronics International Inc.63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • www.Buy-EI.com5/5/93Rev. H: 2/17/05Operating

Strany 2 - Important Notice

82. “REM” (Remaining) Display Mode:In the “REM” (Fuel Remaining) Display Mode, the FP-5(L) willdisplay the fuel in the aircraft tanks as follows:A. W

Strany 3 - Contents

9Example: * You start your flight with full tank(s) and go fly. * You land and pull up to the pumps, taking on 30.0 gallons of fuel. * The FP

Strany 4

c) To Exit - To exit the "Auto Calibration Mode", momentarily push both “PRG” buttons at thesame time. The new K Factor will be displayed f

Strany 5 - Operating Instructions

11than when it was tested at the factory. To insure accuracy, which is essential, the FP-5(L) provides a pilot-programmable K Factor to correct for t

Strany 6 - Upper Bar Showing

126. “T. to E. / MPG” (Time to Empty / Miles per Gallon) Display Mode:"Time to Empty" is calculated by dividing "Fuel Remaining"

Strany 7

13Also, the "AUX" channel can be set up to display a decimal point (for pressure, volts, etc. measurements) anddisplay "00" for re

Strany 8

14show " " (note the tick mark in the upper left corner of the display). If the baud rate is correct but theground speed and distance to

Strany 9

1. Setting the display for “Gal”, "br Gal", “Lbs” or "Ltr" in the "Flow" Display Mode:In the "FLOW" Display M

Strany 10

this alarm is 30 minutes’ worth of fuel (at cruise) for a VFR pilot or 45 minutes for an IFR pilot. In the“REM” display mode a bar in the lower left

Strany 11 - Blinking Digit

Reoccurring Fuel Used Alarm - The Reoccurring Fuel Used Alarm may be programmed to blink the LowFuel Warning LED each time the fuel used reaches the p

Strany 12

FP-5 and FP-5LImportant Notice********** Must Read **********If you think it is not important to read this manual, you're wrong! This manualcont

Strany 13

set to the highest acceptable level for the function measured. In the “AUX” Display Mode a bar in the upperleft corner of the display will be shown w

Strany 14 - 1:22 n 9.3 10.7

Power-Up Programmable Settings:Power-Up Programmable Settings:Power-Up Programmable Settings:Power-Up Programmable Settings:Power-Up Programmable Sett

Strany 15

3. The ability of the line attendant to fill the tank to the same mark. Also, the shape of the tank and thedihedral of the wings can aggravate the s

Strany 16 - Pilot-Programmable Settings:

B. Program the Fuel Flow Setting in the FP-5(L) using the following formula: FF@75% rich x 75Fuel Flow Setting = --------

Strany 17

B. To display a decimal point in the AUX Display Mode, set the AUX Channel Control Setting #2to "000." The decimal point would be used when

Strany 18 - Blinking Digit (0)

11. Scan Rate:The Scan Rate (the time the FP-5(L) takes to switch between display modes) canbe set from 0 to 9 seconds. A "0" setting disa

Strany 19

24Specifications and Operating FeaturesModel:FP-5 and FP-5L (Fuel Flow/Pressure Instrument)Case Dimensions:2.5" x 2.5" x 3.65" depth, 2

Strany 20 - Blinking Digits (15)

Max Displayed Range (Instrument Only):Fuel Flow: 199.9 Gals/Hr or 162.0 br Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.Fuel Remaining: 999 Gals. or 811 br Gal

Strany 21

ContentsWWWWWarranty ...arranty ...

Strany 22

2WWWWWarranty / Agreementarranty / Agreementarranty / Agreementarranty / Agreementarranty / AgreementElectronics International Inc. (E.I. inc.) warran

Strany 23 - Blinking Digits

FP-5 and FP-5LOperating InstructionsSystem Description:System Description:System Description:System Description:System Description:The FP-5 and FP-5L

Strany 24

4In addition to these seven display modes both units have the following pilot programmable settings (used toset up the display and alarms): Display in

Strany 25

B. Second Low Fuel Alarm: This alarm should be set as a warning (example: 5 gallons). When theAlarm Limit is violated the red Low Fuel Warning LED w

Strany 26

6Display Modes and Operating Features:Display Modes and Operating Features:Display Modes and Operating Features:Display Modes and Operating Features:D

Strany 27

7When displaying Fuel Flow, the FP-5(L) will operate as follows:A. When set to display in Gallons the display will read in .1 Gal/Hr increments up to